Welcome to www.epe.sdu.edu.cn !
EN   |   中文
Research Facilities
Research Facilities

(1) LaboratoryEnergy and Environment System Engineering

 

High-Speed Television System for Motion Analysis

Key FeaturesA high-speed television camera and recorder system records images up to 2000 full frames/sec, or 12,000 partial frames/sec. The system employs a unique parallel recording format and solid state image sensor to record information at a maximum rate of 100 million pixels/sec.

Pictures

 

Solid Thermal Conductivity Measurement System

Key FeaturesLinear thermal conductivity of solids

Pictures

 

Heat Pipe/Loop Heat Pipe Performance Test Platform

Key FeaturesBase on this platform, many kinds of HP/LHP performance can be tested. Including starting characteristics, heat transfer performance, isothermal characteristics and so on.

Pictures

 

Vacuum drying and sintering system

Key FeaturesPreparation and sintering of capillary wick.

Pictures

  

Heat Pipe Filling and Welding Platform

Key FeaturesTo produce the testing HP/LHP.

Pictures

 

Performance Test Platform for Heat Exchanger

Key FeaturesTo test the flow and heat transfer characteristics of fluids in heat exchangers.

Pictures

 


(2) LaboratoryInstitute of Thermal Sciences

Electrical Capacitance Tomography

Electrical capacitance tomography is a method for determination of the dielectric permittivity distribution in the interior of an object from external capacitance measurements. Potential applications include the measurement of flow of fluids in pipes and measurement of the concentration of one fluid in another, or the distribution of a solid in a fluid.

 

Thermal Conductivity Analyzer

The Thermal Conductivity Analyzer employs the Modified Transient Plane Source (MTPS) technique in characterizing the thermal conductivity of materials. It employs a one-sided, interfacial heat reflectance sensor that applies a momentary constant heat source to the sample. Typically, the measurement pulse is between 1 to 3 seconds. Thermal conductivity is measured directly, providing a detailed overview of the heat transfer properties of the sample material.

 

Thermal Infrared Imager

A thermal imager is a non-contact temperature measurement device. Thermal Imagers detect the infrared energy emitted, transmitted or reflected by all materials -- at temperatures above absolute zero-- and converts the energy factor into a temperature reading or thermogram.

 

High-speed camera system

A high-speed camera is a device capable of capturing moving images with exposures of less than 1/1,000 second or frame rates in excess of 250 frames per second. It is used for recording fast-moving objects as photographic images onto a storage medium. After recording, the images stored on the medium can be played back in slow motion.

 

Differential scanning calorimeter

Differential scanning calorimetry or DSC is a thermoanalytical technique in which the difference in the amount of heat required to increase the temperature of a sample and reference is measured as a function of temperature. Both the sample and reference are maintained at nearly the same temperature throughout the experiment.

 

Optical Contact Angle Measuring Device

Optical Contact Angle Measuring Device is an easy-to-use, reliable instrument for measuring contact angle. From a simple wetting test to the accurate measurement of surface free energy (SFE), the robust instrument provides flexible options for analyzing wetting and adhesion on solid surfaces. Its rapid, manual operation makes this device outstandingly suitable for occasional wetting measurements with changing tasks and sample types.

 

High performance server

High performance server is the use of parallel processing for running advanced application programs efficiently, reliably and quickly.

 

Electric heating steam generator

Electric heating steam generator is a new way of heating, pollution-free, green environmental protection. No combustion cabinet and no necessity of a chimney: Thus it is not necessary to take the heat loss into consideration and the heat efficiency almost amounts to 98%. The electric heating steam generator can meet the strictest standards for emission and fire prevention. Stepwise time-dividing input method is adopted to control the electric heating elements, thus facilitating users to flexibly adjust the heat productivity of the generator. It will not take long for the generator to start or stop. The adjustment range of the operational load is wide and the operation is simple.

 

 

(3) LaboratoryEnergy and Environmental Engineering

Equipment number

Name

Model

Function

1203433S

On-line monitoring system for mercury freedom

CEMS i

Hg0,Hg1+,Hg2+ and total Hg could be analyzed on-line.

1111059S

GC-MS analyzer

ISQ

Organic compounds with molecular weihgt lower than 1000 could be  analyzed qualitatively and quantitatively.

1111058S

In situ diffuse Reflectance Infrared Fourier Transform Spectroscopy 

Nicolet6700

Functional groups of solid, liquid and gas could be characterized.

1107457S

ICP-OES

OPTIMA 7000DV

Heavy metal elements could be anlyzed quantitatively.

1102405S

Electrical Low Pressure Impactor

ELPI-01

Particulate disrtibution and concentration could be analyzed between 30nm and 10 μm.

1014649S

Energy Dispersion X-ray Fluorescence Spectrometer

QUANT X

Semi-quantitative analysis of  elements and components of solid samples could be finished .

0801300S

Fourier transform infrared gas analyzer

Gasmet dx4000

31 kinds of gases could be analyzed quantitatively and simutaneously.

1215239S

CEMS

SCS-900

O2,SO2,NO and NO2 could be analyzed on-line.

 


Copyright © 2019 School of Energy and Power Engineering, Shandong University. All rights reserved.
ADD:No.17923, Jingshi Rd., Jinan, Shandong, China. CODE:250061 TEL:+86-531-88392701 FAX:+86-531-88392701